GROUP- B

ROOM CONVERSION

Conversion of normal Room into an Environment Controlled Room, Tissue Culture Room, Cold storage Room, or a Gene Bank Room

Available room space can be converted into Environment Controlled Rooms for carrying Tissue Culture and allied work and storage. Required Humidity and Temperatures are created and maintained near naural light covering solar spectrum are created. Parameters of Humidity, Photoperiodic Simulation, and Temperature are controlled with State of the Art, microprocessor based controllers with digital display of each parameter separately or on a single panel. The Control Panel can be positioned inside the room or outside for minimum door opening frequencies for better quarantine effect. Depending on the nature of the work,walk in working space is catered for. Heat convector, Air conditioner, ceiling, wall and floor insulation are done keeping in mind the temperature to be achieved and exposure to sun, heat emission and working equipment and human heat load. Tissue culture Castor Racks are used for better mobility, working space and sensitive experimentation. A pre entry/buffer zone with air curtain is also provided on specific user requirement. Shelves,tables or mobile racks are provided depending on requirement and type of working space required. Minimum infrastructure/instruments for standard room conversion size (10' x 10' x 10') or (3.03 Mtr. X 3.03 Mtr. X 3.03 Mtr) V-02201

 
     
 
Wall insulation with Polyurethane (puff) and Bison paneling (36.72 sq.m.area).  
     
Ceiling insulation with Polyurethane and polymer covering (9.18 sq.m. area).  
     
Floor insulation polyvinyl (9.18sq.m. area)  
     
Temperature range 15o C to 35o C ± 1 digit..  
     
Tissue culture castor rack with PAR (Photosynthetically Active Radiation); PAR-2 Tube lights as per Din & IEC Standards Code V-0231 Two Units and Four Unis of Code V-0230.  
     
Temperature based Micron Environment Controller (AC) 1.5 Ton Capacity Code3 V-02424 Three Units.  
     
Microprocessor Temperature Controller Code V-0240 or V-0246 One Unit.  
     
Heat Converter Code V-02436 Two Units.  
     
Sequential Timer Code V-02419 One Unit.  
     
Photoperiodic Timer Code V-02415 One Unit.  
     
Switching Unit Code V-02435 One Unit.  
     
Vapour Humidiffier Code V-02428 Two Units.  
     
Humidity Controller Code V-02425 One Unit.  
     
Air curtain One Unit.  
 
     
     
   
 
 
 