GROUP- D

BIOTECH INSTRUMENTS

TEMPERATURE CONTROLLERS


V-0240 TEMPERATURE CONTROLLER MICROPROCESSOR
Specifications : It controls temperature with ± 0.1 Degree C of Tissue Culture Rooms, Growth Rooms, Hardening Rooms, Specific Rooms for controlling the required Temperature by using 1.5 Ton air conditioner and 4.4 KVA heaters to provide integral environment temperature control. 1.5 Ton airconditioners and 4.4 KVA heat convectors can be directly connected to the powered out put. Input 200 V -220 V AC, 50 Hz, single phase.


Salient Features :
 
     
  Real time microprocessor based user programmable controller.  
       
  4 digit LED display for displaying measured values and another 4-digit LED display for displaying settings.  
       
  Feather touch operation.  
       
 


Platinum sensor probe Pt-100 (Class A, SI sensor,cable 5M, mac var + 0.20 Degree C , resistance standard 100 ohms, self heating error in Oo c/m 0.6 in flowing air V-1 m/s and 0.24 in still air, response time in moving air 50% response in 6 sec and 80% response in 5 secs.
 
       
  Set point lock within the setting panel to protect setting changes.  
       
  Level lock to ensure that the parameter can be read but cannot be changed.  
       
  Sensor failure indication  
       
  Selection of unit Degree C, Degree F.  
       
  Display resolution 0.1 Degree  
       
  Accuracy ± 0.1 Degree C  
       
  Automatic hysteresis control  
       
  Audio visual alarm for higher temperature ranges  
       
  Wide selectable temperature range. Ranges from 200 Degree to 600 Degree C.  
       
  Variable delay selectable 0-240 sec.  
       
 

4 Independent powered outputs used to actuate and operate directly upto 1.5 ton air-conditioners and 4.4 KVA heat convectors, Input 200V-220V AC, 50 Hz,Single phase.  
       
  Code No.V-02419 is not required with this controller  
       
  Ambient 5 Degree C to 5 Degree , RH upto 90%  
       
 

V-0241

V-0242

V-0243


V-0244

TEMPERATURE CONTROLLER MICROPROCESSOR

Three independent powered outputs, V-0240 Microprocessor Loaded

Two independent powered outputs, V-0240 microprocessor Loaded.

It is basically V-0240 with PID control 4-Level PVSV display, auto tuning with ramp and soak. Function Control SPST relay.

It is basically V-0240 with PID control 4-level, auto tuning with ramp and Soak Function. Control voltage pulse.
 
       
 
V-0245
MIRSMP TEMPERATURE CONTROLLER MICROCLMATIC

Specification: Real time microprocessor based temperature controller range 0.1o - 59oc. Accuracy better than ± 1° C. Hysterisis 0.4°C LED display with 4 indipendent powered outputs, each outputs can operate upto 1.5 ton AC and 4.4 KVA heaer, preferably with 4 cooling heating points auto select audio visual alarm facility incorporated, with plainim secsor prob PT- 100 (class A, Si sensor, cable 5m, max var ± 0.20°C, resistance standard 100ohms, self heating error in 0°c/mW 0.6 in flowing a V-1 m/s and 0.24 in still air, Response time in moving air 50% responsein 6 sec and 80% response in 20 sec. Accessory switching unit incorporated input - 110/220V AC, 50Hz single phase. Ambient Tempraure-5°C to 50°C, RH-upo 90%. Code V-02419 is not required with this controller.)
 
 
       
 
V-0246 DIGITAL TEMPERATURE CONTROLLER (TWO SET POINT)

Digital CMOS controlling with hysterisis monitored accompanied with 24 hrs. Functional span. 1.5 ton airconditioner and 4.4. KVA heat convector can be directly connected to the powered out put. Input-200-240 VAC, 50 Hz. Single phase, Ambient 5O C to 50O C, RH upto 90%

Specificaions: Temprature range:0.1° - 59.9°C wih accuracy ± 1°C, Resolution 0.1, display 3½ digits,0.5", 7 segment red LED. Temp seting by front panel key switch and Trimpot. Sensor Pt-100 (A class) with 5m cord. Additional hysteresis 0.4°C. Deley 2/3 minutes for comressor, 1.5 ton AC and 4.4 KVA heater directly connected to he output. Input 200-240 VAC, 50Hz, single phase, ambient 5°C to 50°C, RH upto 90%.
 
       
 
V-0247 DIGITAL TEMPERATURE CONTROLLER (SINGLE SET POINT)

It is V-0246 with single set point.
 
 
     
 
V-0248 DIGITAL TEMPERATURE CONTROLLER ANALOGUE

Specifications : Temperature 0-50 OC ,accuracy -2 OC, delay 2 min for air conditioner 1.5 ton airconditioner and 4.4 KVA heater directly connected to the output input 200-240 A.C 50Hz, single phase, Ambient 5 OC to 50 OC, RH upto 90%
 
     
 
V-0249 AXIOMATIC TEMPERATURE CONTROLLER

A DIN standard analogue temperature controller designed for us with type J or K thermocouples or an RTD. The instrument generates a time proportional controlled output, and has a master set point which can be rotated over a clearly defined scale and locked. An analogue deviation meter is mounted above the scale. The unit is mains powered with output via a relay.

Specifications: Range : OOC-1200 0C

Supply Voltage : 240/120 V AC, 50 Hz.

Relay contact ratings : S.P.D.T 240 V AC/.25 Amp.
 
     
 
V-2410
SENSOR PT - 100

Platinum sensor probe Pt - 100 (class A, SI sensor, cable 5m,max var -0.20 OC, resistance standard 100 ohms, self heating error in OO c/m W 0.6 in flowing air V-1 m/s and 0.24 in still air, Response time in moving air 50% response in 6 sec and 80% response in 20 sec.
 
     
 
V-02411
SENSOR PT - 100 FAST RESPONSE

It is basically Code V-02410 with 80% response in 6 sec.
 
     
 
V-02412 TEMPERATURE, HUMIDITY, PHOTOPERIODIC MONITOR PANEL.

Specific for Greenhouses, Growth Chambers, Playhouses, Nethouses and any other specific Houses & Chambers.

Temperature (Code C-0240), Humidity (Code-V-02425), Photoperiodic (Code-V-02415) microprocessor with light monitoring system Accuracy temperature control ±10C humidity control ±2%, photoperiodic control ±1 Sec/day are collectively mounted in a combined cabinet with a common front panel with different controls and indicators for ease of operation and easy access.


   
   
 
     
 
V-02413 PHOTOPERIODIC TIMER ANALOGUE

Specifications : 24 hrs. repeat cycle.Min.on/off period 10/15 min with NICAD battery auto recharging. Powered output can drive 110 tube light of 40W directly. Thermal safety 16 Amp inbuilt. Accuracy ±8 Sec/day. Input - 110/220 V AC, 50 Hz Single phase. Ambient Temperature 5 O - 50 OC, RH upto 95%.
   
V02414 DIGITAL PHOTOPERIODIC TIMER

Specifications: It operates lights autometically everyday as per photoperiodic time. 110 tube lights of 40/60 Watt each can be operated directly from the powered output. Weekly settings available for 14 periods 7 On -7 Off can be available in one day. Accuracy ± 1 sec/day. NiCad battery backup upto 90 min, auto recharging is provided. INPUT - 110/220 V AC, 50Hz Phase single. Ambient 5°C to 50°C, RH-upto 95%.





 
     
 

V-02415

 

 

 

 

 

 

 

 

 


V-02416

PHOTOPERIODIC TIMER PROGRAMMABLE

Specifications:

• Real time microprocessor based.

• Accuracy ± 1sec./day.

• Resolution 1 min.

• Weekly setting available for 14 periods.

• 8 ON & 8 OFF in single day.

• Copy facility to repeat a set sequence on one or more week days.

• Digial selector.

• Auto reset during power failure.

• Cyclic ON/OFF with NiCad battery backup upto recharging.

• Thermal safely 16 Amp.

• Auto manual selecable.

• LCD display.

It is basically advance microprocessor version of V-02415 with timer pulse revivification facility . Integral calendar with automatic winter/summer time change on last Saturday in March/October respectively.

 

 
     
 
V-02417








DIGITAL CYCLIC TIMER

Specific for fogging, misting system, Humidifier, dehumidifier controlled by timer.

Specificaions: 0-999 Min/sec On, 0-999 Min./sec off automatic cycling. Accurate quartz Power output can directly humidifier / De-humidifier / other electrical load upto4.4 KVA. Input 200 V to 240V, A.C., Phase-Single 50Hz. Ambient 5°C to 50°C, RH upto 90%.
 
     
 
V-02418 DIGITAL CYCLIC TIMER

It is basically V-02417 with 2/3/4 digits, outputs latched/auto reset, there are less moving parts, hence much reliable.
 
     
 
V-02419 SEQUENTIAL TIMER

It operates two air conditioners upto 1.5 - 2 ton capacity each alternately, directly from the powered output of timer.

Specifications: Min. ON/OFF cycle 15 min. Niced backup upto 90 min, auto recharging, auto manual selectable. INPUT - 110/220 V A.C., 50 Hz single pahse, Ambient 5°C to 50°C, RH upto 90%.


 
     
 
V-02420 AXIOMATIC TIMER

It operates four air conditioner upto 1.5 Ton capacity each alternately directly from powered output to timer.

Specifications: It is V-02419 with double controll sysems.

 
 
V-02421 OZONE GENERATION SYSTEM

It is used for ionic disinfection of Tissue Culture Room, Hardening Room, Cold Room & Other specified rooms. Dry disinfection area 18 m3, upto 90-95%.

Specifications: Wavelength 185 nm, Amp-2, disinfection time 60 minutes. Auostop timer, Hazardous Area available for entry after10 minutes of disinfection . Power Drive unit also provided seperately.

Input 200-240V A.C., 50Hz, Phase-single, Ambient 5°C to 50°C. RH upto 90%, O3 monitor analogue.



 
 
V-02422 FOR 35 M3 Area

It is basically V-02421
   
V-02423 FOR 100 M3 Area

It is basically V-02421
   
V-02424 HEAVY DUTY AIR-CONDITIONER FOR BIOTECH PURPOSE

Specifically designed for Tissue Culture Rooms, Hardening Rooms or any other related work.

Specifications: Capacity 1.5 TR, super silent, power saving compressor (Kirloskar/ Carrier make) with low voltage start with PTCR, uniform colling, slide in slide out of divice, air circulation 480 cubic ft/min ( High ) grooved copper tubing , cooling capacity 18300 BTU/hr., NE1900 running current 10.2 a, power 2150 w, Kcal/h 4610, size: 455 mm x 760 mm. Input 200-240 V AC, 50 Hz, single phase. Ambient 5°C to 50°C, RH upto 90%.
 
     
 
  HUMIDITY CONTROLLERS
 
     
 
V-02425








MICROPROCESSOR MICROCLIMATICE DIGITAL HUMIDITY CONTROLLER (Inetroduced first time in India)

Specificaions: • Real Time Microprocessor based • On/Off control for Humidifying/ Dehumidifying • Hysteresis / Differential 1% - 9% • Deley timer 0-240 sec. • Direct / Reverse selectable • Lock function to preven miss operating • Feaher touch operation • Fast responce sensor, line resistance < 10 W • Display Accuracy - indicating value ± 0.2% ± 1 digit. Input -220 - 240 VAC, 50 Hz. Single phase, Ambient 5°C to 50°C, RH upto 90%.
 
 
V-02426 HUMIDITY CONTROLLER (ANALOGUE)

Through Analogue controls with stand by provision, Controlling range : 20%-80% accuracy ± 8% Input - 200-240 VAC, 50 Hz. Single phase, Ambient 5o C to 50 Degree C, RH upto 90%
   
V-02427

DIGITAL HUMIDITY CONTROLLER

Humidity range 20% to 95%. Accuracy ± 2% Display 3/½ digit, 0.5", 7 segment red LED Setting by front panel key switch and multiturm potentiometer (TRIMPOT). Working on Dry and Wet Bulb principle. Sensor Pt-100 powered output can be directly connected to upto 4.4 KVA humidifier / dehumidifier Input 200 V to 240 VA.C, 50 Hz. Ambient 5°C to 50°C, RH upto 90%.


 
     
 
V-02428 VAPOUR HUMIDIFIER

It creates the simulated natural humidity in Tissue Culture rooms,Growth rooms Hardening rooms or any other specific rooms.

Specificaions: Simulated natural vapours 1.5/2 KVA. Automatic cut off device incorporated. In continuous running position water consumption 1 ltr. per hour. Mechanical float fitting in sub storage unit. One unit suitable for maximum room size:- 10'x8'x8' or 18 Cubic Meters. Thermal isolation reduces energy losses during off period. Input 200V to 240VAC, 50Hz., Phase-Single, Ambient - 5°C to 50°C, RH upto 90%.
 
     
 
V-02429 HUMIDIFIER COLD

Specificaions:
Microfogging spraying humidifier. Cabinet made up of Stainless steel, totally enclosed fan cooled motor. Humidifier can be directly connected to the Humidity controller. Droplet size 70µm Input - 200 - 240V AC, 50 Hz., Single phase., Ambient 5°C to 50°C, RH upto 90%.
 
     
 
V-02430 MISTING UNIT

It produces natural fogging or humidity for Green Houses, Poly Houses, Net Houses, or any other specific Houses to achieve RH-90 to 95% humidity.

Specificaions: DAN (Isreal) micro fogging / micro misting system, with micro filter unit, return gutter, control valve assembly, pressure gauge, 12 Nozzles, Static pump 1/1.5 HP, 50'PVC pipe. Polymer water storage tank 500 litre capacity for 60 sq meter area by using 72 nozzles with pipe. Fogger discharge range- 7.0 LPH, Operating Pressure- 4.0 bar, Density of one fogger- 4.0 m, Droplet size - 70 micron.
   
V-02431 It is basically V-02430 with manifold cross 4-nozzle type to achieve very high humidity.
   
V-02432 It is basically V-02430 for 100 sqm x 2 m size.
   
V-02433 ROOM FOGGING SYSTEM

Water droplets size 10 micron, for room size 50 sq. meters.
   
V-02434 SCHUTZ ELECTRONIC FOR HUMIDITY

Specifically designed for Humidifier to control its water input as well as output supply. It protects the running & heating parts or humidifier from dry running and heating parts of humidifier from dry running and getting burnt. Automatic operation for input water supply. Input 200-240 VAC, 50 Hz,Single phase.Ambient 5°C to 50°C, RH upto 90%.
   
V-02435 SWITCHING UNIT

Specifically designed to operate Air conditioner up to 2 Ton/Heat convector upto 4.4. KVA load or 110 tube lights. Input 200-240 VAC, 50 Hz, single phase.Ambient 5°C to 50°C, RH upto 90%.
   
V-02436 HEAT CONVECTOR

Specifically designed for Tissue Culture Rooms, Hardening Rooms or any other related work.

Specificaions: In built auto thermal cut off device, Biotech grade 2/2.4 KW heater, variable speed selector switch, selective combustive material chosen for minimum utilisation for atmospheric oxygen, Input 200-240 VAC, 50 Hz, single phase, Ambient 5°C to 50°C, RH upto 90%.
   
V-023043 FLUORESCENT TUBE LIGHT (PHILIPS/OSRAM MAKE) 40/58W

Standard designs provided.
   
V-023044 PHOTOSYNTHETICALLY ACTIVE RADIATION LIGHT (PAR)

According to DIN & IEC standard (Spectrum 380 nm - 780 nm)
   
V-023045 BALLAST SOLID STATE FOR SIMULATED LIGHT

Electronic simulator to operate fluorescent tube 40/58 watt.

Specificaions: Natural simulated light spectrum, flicker free radiations, low voltage start, plus 0.8 power factor, resistant to stroboscopic effect, no RF leakage, Operating range 100 V - 300 v minimum power consuption. Light inensity 6 Klux at 20 cm and performance certified by Directorate Ministry of Information Technology, Govt. of India, vide certificate no. ERTL(N)90(A)-2KICO685.
   
V-023046 PHOTOSIMULATOR FOR PAR

(PHOTOSYNTHETICALLY ACTIVE RADIATION)LIGHT


Electronic simulator to operate PAR Light 36 watt having wave length 380 nm - 780nm

Specificaions: Natural simulated light spectrum, flicker free radiations, low voltage start, plus 0.8 power factor, resistant to stroboscopic effect, no RF leakage, Operating range 100 V - 300 v minimum heat losses, minimum power consuption. Light intensity6 Klux at 15 cm distance and 8 Klux at source ERTL tested and approved.
   
V-02437 DIGITAL LUX METER

A hand held digital light meter with integral sensor indicating light intensities in lux.

Specificaions: The sensor, conisting of selenium photovoltiac cells is connected to he meter by a 1 meter coiled lead.

• 3 switch selectable ranges : • 0.1999 lux (resolution 1 lux) • 1999-19999 lux (resolution 10 lux) • 19999-50,000 lux (resolution 100 lux) • Accuracy typically ± 10% of reading -2counts • 31/2 digit, • 13mm high Liquid Crystal Display • Requires 9V PP3 battery for operation.
   
V-02438 DIGITAL LUX METER

A hand held digital light meter for indicating light intensities in lux.

Specificaions: The sensor connects to the base of the meter via 5 pin DIN connector and a 1 meter coiled lead.

• 3 switch selectable ranges : • 0.2000 lux (resolution 1 lux) • 2000-20.000 lux (resolution 10 lux) • 20,000-100,000 lux (resolution 100 lux) • Accuracy typically ± 9% • Display hold • 3½ digit 13mm high Liquid Crystal Display.
 
   
 
V-0230 TISSUE CULTURE CASTOR RACK

Used for Tissue culture, Hardening & related work. Provides natural simulated light.

Specifications: Height 5' 8", Width 4' 2", Lenght 18", Shelves 5, lighting facility in 4 shelves. Shelf to shelf distance 16". Shelf 50" x 18", 3mm thick glass / Hylem Citylam sheet in each shelf. Four tube lights 40 Wattflourescent cription filled and 4 x 25 Watt incandescent lamps with individual on/off switch in each shelf. Light intensity 3 Klux 5cm above the shelf surface 10 klux at the source. Sixteen Solid State Ballats (Code V-023045), Electronic ballasts are specially tested and approved by ERTL for use upto 300 V. Frame mild seel 2.5 x 2.5 cm C.R.C. sq. pipe with anti corossive, humidity resistant Powder Coating, Caster -4., Trolly can be connected directly to Photoperiodic timer output, (Code V-02413 or V-02415).

Input : 200-240V A.C, 50 Hz, Single Phase, Ambient 5 Degree C to 50 degree C,RH upto 95.


 
 
V-0231 TISSUE CULTURE CASTOR RACK

With PAR (Photosynthetically Active Radiation) light used for Tissue culture, Hardening and related work for higher carbon fixation and night break technique by providing natural spectrum of light intensity having wave length 380 nm-780 nm.

Specifications: Height 5' 8", Width 4' 2", Lenght 18", Shelves 5, lighting facility in 4 shelves. Shelf to shelf distance 16". Shelf 50" x 18", 3 thick glass / Hylem Citylam sheet in each shelf. 4 x 36 Watt PAR (Photosynthetically active radiation) lamps in one shelf with individual on/off switch. Four tube lights 40 Wattflourescent cription filled and 4 x 25 Watt incandescent lamps with individual on/off switch in each shelf. Light intensity 3 Klux 5cm above the shelf surface 10 klux at the source. Sixteen Solid State Photonimulaor (Code V-023046), frame mild steel 2.5 x 2.5 cm C.R.C. sq. pipe with anti corossive, humidity resistant Powder Coated, Caster -4., Trolly can be connected directly to Photoperiodic timer output, (Code V-02413 or V-02415).

Input : 200-240 V,AC,50 Hz,Single phase, Ambient 5 oC to 50 oC,Rh upto 95%
   
V-0232 TISSUE CULTURE CASTOR RACK (SS)

Basically Code V-0230 with stainless steel structure.
   
V-0233 TISSUE CULTURE CASTOR RACK (SS) PLATINUM

Basically Code V-0230 with stainless Steel Structure with Photosimulator electronic ballast.
 
   
 
 
 
  © 2004 Vista Biocell Pvt. Ltd. All right reserved.
Website Designed by: UNIQUE SOFTS
Unique Softs