GROUP- D
BIOTECH INSTRUMENTS
TEMPERATURE CONTROLLERS
| V-0240 |
TEMPERATURE CONTROLLER
MICROPROCESSOR
Specifications : It controls temperature
with ± 0.1 Degree C of Tissue Culture
Rooms, Growth Rooms, Hardening Rooms, Specific
Rooms for controlling the required Temperature
by using 1.5 Ton air conditioner and 4.4
KVA heaters to provide integral environment
temperature control. 1.5 Ton airconditioners
and 4.4 KVA heat convectors can be directly
connected to the powered out put. Input
200 V -220 V AC, 50 Hz, single phase. |
Salient Features :
|
|
|
| |
|
|
| |
 |
Real time microprocessor based user programmable
controller. |
|
| |
|
|
|
| |
 |
4 digit LED display for displaying measured
values and another 4-digit LED display for displaying
settings. |
|
| |
|
|
|
| |
 |
Feather touch operation. |
|
| |
|
|
|
| |

|
Platinum sensor probe Pt-100 (Class
A, SI sensor,cable 5M, mac var + 0.20 Degree C , resistance
standard 100 ohms, self heating error in Oo c/m 0.6
in flowing air V-1 m/s and 0.24 in still air, response
time in moving air 50% response in 6 sec and 80% response
in 5 secs.
|
|
| |
|
|
|
| |
 |
Set point lock within the setting panel
to protect setting changes. |
|
| |
|
|
|
| |
 |
Level lock to ensure that the parameter
can be read but cannot be changed. |
|
| |
|
|
|
| |
 |
Sensor failure indication |
|
| |
|
|
|
| |
 |
Selection of unit Degree C, Degree F. |
|
| |
|
|
|
| |
 |
Display resolution 0.1 Degree |
|
| |
|
|
|
| |
 |
Accuracy ± 0.1 Degree C |
|
| |
|
|
|
| |
 |
Automatic hysteresis control |
|
| |
|
|
|
| |
 |
Audio visual alarm for higher temperature
ranges |
|
| |
|
|
|
| |
 |
Wide selectable temperature range. Ranges
from 200 Degree to 600 Degree C. |
|
| |
|
|
|
| |
 |
Variable delay selectable 0-240 sec. |
|
| |
|
|
|
| |

|
4 Independent powered outputs used to actuate
and operate directly upto 1.5 ton air-conditioners and
4.4 KVA heat convectors, Input 200V-220V AC, 50 Hz,Single
phase. |
|
| |
|
|
|
| |
 |
Code No.V-02419 is not required with this
controller |
|
| |
|
|
|
| |
 |
Ambient 5 Degree C to 5 Degree , RH upto
90% |
|
| |
|
|
|
| |
|
V-0241
V-0242
V-0243
V-0244
|
TEMPERATURE
CONTROLLER MICROPROCESSOR
Three independent powered outputs, V-0240 Microprocessor
Loaded
Two independent powered outputs, V-0240 microprocessor
Loaded.
It is basically V-0240 with PID control 4-Level
PVSV display, auto tuning with ramp and soak. Function
Control SPST relay.
It is basically V-0240 with PID control 4-level,
auto tuning with ramp and Soak Function. Control
voltage pulse. |
|
|
| |
|
|
|
| |
|
V-0245
|
MIRSMP TEMPERATURE CONTROLLER MICROCLMATIC
Specification: Real time microprocessor based temperature controller range 0.1o - 59oc. Accuracy better than ± 1° C. Hysterisis 0.4°C LED display with 4 indipendent powered outputs, each outputs can operate upto 1.5 ton AC and 4.4 KVA heaer, preferably with 4 cooling heating points auto select audio visual alarm facility incorporated, with plainim secsor prob PT- 100 (class A, Si sensor, cable 5m, max var ± 0.20°C, resistance standard 100ohms, self heating error in 0°c/mW 0.6 in flowing a V-1 m/s and 0.24 in still air, Response time in moving air 50% responsein 6 sec and 80% response in 20 sec. Accessory switching unit incorporated input - 110/220V AC, 50Hz single phase. Ambient Tempraure-5°C to 50°C, RH-upo 90%. Code V-02419 is not required with this controller.) |
|
|
|
| |
|
|
|
| |
| V-0246 |
DIGITAL
TEMPERATURE CONTROLLER (TWO SET POINT)
Digital CMOS controlling with hysterisis
monitored accompanied with 24 hrs. Functional
span. 1.5 ton airconditioner and 4.4. KVA
heat convector can be directly connected
to the powered out put. Input-200-240 VAC,
50 Hz. Single phase, Ambient 5O
C to 50O C, RH upto 90%
Specificaions: Temprature range:0.1°
- 59.9°C wih accuracy ± 1°C,
Resolution 0.1, display 3½ digits,0.5",
7 segment red LED. Temp seting by front
panel key switch and Trimpot. Sensor Pt-100
(A class) with 5m cord. Additional hysteresis
0.4°C. Deley 2/3 minutes for comressor,
1.5 ton AC and 4.4 KVA heater directly connected
to he output. Input 200-240 VAC, 50Hz, single
phase, ambient 5°C to 50°C, RH upto
90%.
|
|
 |
|
|
| |
|
|
|
| |
| V-0247 |
DIGITAL
TEMPERATURE CONTROLLER (SINGLE SET POINT)
It is V-0246 with single set point. |
|
|
|
|
| |
|
|
| |
| V-0248 |
DIGITAL
TEMPERATURE CONTROLLER ANALOGUE
Specifications : Temperature 0-50 OC
,accuracy -2 OC, delay 2 min
for air conditioner 1.5 ton airconditioner
and 4.4 KVA heater directly connected to
the output input 200-240 A.C 50Hz, single
phase, Ambient 5 OC to 50 OC,
RH upto 90% |
|
|
|
| |
|
|
| |
| V-0249 |
AXIOMATIC
TEMPERATURE CONTROLLER
A DIN standard analogue temperature controller
designed for us with type J or K thermocouples
or an RTD. The instrument generates a time
proportional controlled output, and has
a master set point which can be rotated
over a clearly defined scale and locked.
An analogue deviation meter is mounted above
the scale. The unit is mains powered with
output via a relay.
Specifications: Range : OOC-1200
0C
Supply Voltage : 240/120 V AC, 50 Hz.
Relay contact ratings : S.P.D.T 240 V AC/.25
Amp. |
|
|
|
| |
|
|
| |
|
V-2410
|
SENSOR PT - 100
Platinum sensor probe Pt - 100 (class A, SI sensor,
cable 5m,max var -0.20 OC, resistance
standard 100 ohms, self heating error in OO
c/m W 0.6 in flowing air V-1 m/s and 0.24 in still
air, Response time in moving air 50% response in
6 sec and 80% response in 20 sec. |
|
|
| |
|
|
| |
|
V-02411
|
SENSOR PT - 100
FAST RESPONSE
It is basically Code V-02410 with 80% response in
6 sec. |
|
|
| |
|
|
| |
| V-02412 |
TEMPERATURE,
HUMIDITY, PHOTOPERIODIC MONITOR PANEL.
Specific for Greenhouses, Growth Chambers,
Playhouses, Nethouses and any other specific
Houses & Chambers.
Temperature (Code C-0240), Humidity (Code-V-02425),
Photoperiodic (Code-V-02415) microprocessor
with light monitoring system Accuracy temperature
control ±10C humidity
control ±2%, photoperiodic control
±1 Sec/day are collectively mounted
in a combined cabinet with a common front
panel with different controls and indicators
for ease of operation and easy access. |
|

 |
| |
|
| |
|
|
|
| |
|
|
| |
| V-02413 |
PHOTOPERIODIC
TIMER ANALOGUE
Specifications : 24 hrs. repeat cycle.Min.on/off
period 10/15 min with NICAD battery auto
recharging. Powered output can drive 110
tube light of 40W directly. Thermal safety
16 Amp inbuilt. Accuracy ±8 Sec/day.
Input - 110/220 V AC, 50 Hz Single phase.
Ambient Temperature 5 O - 50
OC, RH upto 95%. |
| |
|
| V02414 |
DIGITAL PHOTOPERIODIC
TIMER
Specifications: It operates lights
autometically everyday as per photoperiodic
time. 110 tube lights of 40/60 Watt each
can be operated directly from the powered
output. Weekly settings available for 14
periods 7 On -7 Off can be available in
one day. Accuracy ± 1 sec/day. NiCad
battery backup upto 90 min, auto recharging
is provided. INPUT - 110/220 V AC, 50Hz
Phase single. Ambient 5°C to 50°C,
RH-upto 95%. |
|

 |
|
|
| |
|
|
| |
|
V-02415
V-02416
|
PHOTOPERIODIC TIMER
PROGRAMMABLE
Specifications:
• Real time microprocessor based.
• Accuracy ± 1sec./day.
• Resolution 1 min.
• Weekly setting available for 14 periods.
• 8 ON & 8 OFF in single day.
• Copy facility to repeat a set sequence on
one or more week days.
• Digial selector.
• Auto reset during power failure.
• Cyclic ON/OFF with NiCad battery backup upto
recharging.
• Thermal safely 16 Amp.
• Auto manual selecable.
• LCD display.
It is basically advance microprocessor version of
V-02415 with timer pulse revivification facility
. Integral calendar with automatic winter/summer
time change on last Saturday in March/October respectively.
|
|
|
| |
|
|
| |
V-02417
|
DIGITAL CYCLIC TIMER
Specific for fogging, misting system, Humidifier, dehumidifier controlled by timer.
Specificaions: 0-999 Min/sec On, 0-999 Min./sec off automatic cycling. Accurate quartz Power output can directly humidifier / De-humidifier / other electrical load upto4.4 KVA. Input 200 V to 240V, A.C., Phase-Single 50Hz. Ambient 5°C to 50°C, RH upto 90%. |
 |
|
|
|
| |
|
|
| |
| V-02418 |
DIGITAL
CYCLIC TIMER
It is basically V-02417 with 2/3/4 digits,
outputs latched/auto reset, there are less
moving parts, hence much reliable. |
|
|
|
| |
|
|
| |
| V-02419 |
SEQUENTIAL
TIMER
It operates two air conditioners upto 1.5
- 2 ton capacity each alternately, directly
from the powered output of timer.
Specifications: Min. ON/OFF cycle
15 min. Niced backup upto 90 min, auto recharging,
auto manual selectable. INPUT - 110/220
V A.C., 50 Hz single pahse, Ambient 5°C
to 50°C, RH upto 90%. |
|

 |
|
|
| |
|
|
| |
| V-02420 |
AXIOMATIC
TIMER
It operates four air conditioner upto 1.5
Ton capacity each alternately directly from
powered output to timer.
Specifications: It is V-02419 with
double controll sysems. |
|
|
|
| |
| V-02421 |
OZONE GENERATION
SYSTEM
It is used for ionic disinfection of Tissue
Culture Room, Hardening Room, Cold Room
& Other specified rooms. Dry disinfection
area 18 m3, upto 90-95%.
Specifications: Wavelength 185 nm,
Amp-2, disinfection time 60 minutes. Auostop
timer, Hazardous Area available for entry
after10 minutes of disinfection . Power
Drive unit also provided seperately.
Input 200-240V A.C., 50Hz, Phase-single,
Ambient 5°C to 50°C. RH upto 90%,
O3 monitor analogue.
|
|

 |
|
|
| |
| V-02422 |
FOR 35 M3
Area
It is basically V-02421 |
| |
|
| V-02423 |
FOR 100 M3
Area
It is basically V-02421 |
| |
|
| V-02424 |
HEAVY DUTY AIR-CONDITIONER
FOR BIOTECH PURPOSE
Specifically designed for Tissue Culture Rooms,
Hardening Rooms or any other related work.
Specifications: Capacity 1.5 TR, super silent,
power saving compressor (Kirloskar/ Carrier make)
with low voltage start with PTCR, uniform colling,
slide in slide out of divice, air circulation 480
cubic ft/min ( High ) grooved copper tubing , cooling
capacity 18300 BTU/hr., NE1900 running current 10.2
a, power 2150 w, Kcal/h 4610, size: 455 mm x 760
mm. Input 200-240 V AC, 50 Hz, single phase. Ambient
5°C to 50°C, RH upto 90%. |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
V-02425
|
MICROPROCESSOR MICROCLIMATICE DIGITAL HUMIDITY CONTROLLER (Inetroduced first time in India)
Specificaions: • Real Time Microprocessor based • On/Off control for Humidifying/ Dehumidifying • Hysteresis / Differential 1% - 9% • Deley timer 0-240 sec. • Direct / Reverse selectable • Lock function to preven miss operating • Feaher touch operation • Fast responce sensor, line resistance < 10 W • Display Accuracy - indicating value ± 0.2% ± 1 digit. Input -220 - 240 VAC, 50 Hz. Single phase, Ambient 5°C to 50°C, RH upto 90%. |
|
|
| |
| V-02426 |
HUMIDITY
CONTROLLER (ANALOGUE)
Through Analogue controls with stand by
provision, Controlling range : 20%-80% accuracy
± 8% Input - 200-240 VAC, 50 Hz.
Single phase, Ambient 5o C to
50 Degree C, RH upto 90% |
| |
|
| V-02427 |
DIGITAL HUMIDITY CONTROLLER
Humidity range 20% to 95%. Accuracy ±
2% Display 3/½ digit, 0.5",
7 segment red LED Setting by front panel
key switch and multiturm potentiometer
(TRIMPOT). Working on Dry and Wet Bulb
principle. Sensor Pt-100 powered output
can be directly connected to upto 4.4
KVA humidifier / dehumidifier Input 200
V to 240 VA.C, 50 Hz. Ambient 5°C
to 50°C, RH upto 90%.
|
|
 |
|
|
| |
|
|
| |
| V-02428 |
VAPOUR HUMIDIFIER
It creates the simulated natural humidity in Tissue
Culture rooms,Growth rooms Hardening rooms or any
other specific rooms.
Specificaions: Simulated natural vapours
1.5/2 KVA. Automatic cut off device incorporated.
In continuous running position water consumption
1 ltr. per hour. Mechanical float fitting in sub
storage unit. One unit suitable for maximum room
size:- 10'x8'x8' or 18 Cubic Meters. Thermal isolation
reduces energy losses during off period. Input 200V
to 240VAC, 50Hz., Phase-Single, Ambient - 5°C
to 50°C, RH upto 90%. |
|
|
| |
|
|
| |
| V-02429 |
HUMIDIFIER
COLD
Specificaions: Microfogging spraying humidifier.
Cabinet made up of Stainless steel, totally enclosed
fan cooled motor. Humidifier can be directly connected
to the Humidity controller. Droplet size 70µm
Input - 200 - 240V AC, 50 Hz., Single phase., Ambient
5°C to 50°C, RH upto 90%. |
|
|
| |
|
|
| |
| V-02430 |
MISTING UNIT
It produces natural fogging or humidity for Green
Houses, Poly Houses, Net Houses, or any other specific
Houses to achieve RH-90 to 95% humidity.
Specificaions: DAN (Isreal) micro
fogging / micro misting system, with micro filter
unit, return gutter, control valve assembly, pressure
gauge, 12 Nozzles, Static pump 1/1.5 HP, 50'PVC
pipe. Polymer water storage tank 500 litre capacity
for 60 sq meter area by using 72 nozzles with pipe.
Fogger discharge range- 7.0 LPH, Operating Pressure-
4.0 bar, Density of one fogger- 4.0 m, Droplet size
- 70 micron. |
| |
|
| V-02431 |
It is basically V-02430 with manifold
cross 4-nozzle type to achieve very high humidity.
|
| |
|
| V-02432 |
It is basically V-02430 for 100 sqm
x 2 m size. |
| |
|
| V-02433 |
ROOM FOGGING
SYSTEM
Water droplets size 10 micron, for room size 50
sq. meters. |
| |
|
| V-02434 |
SCHUTZ
ELECTRONIC FOR HUMIDITY
Specifically designed for Humidifier to control
its water input as well as output supply. It protects
the running & heating parts or humidifier from dry
running and heating parts of humidifier from dry
running and getting burnt. Automatic operation for
input water supply. Input 200-240 VAC, 50 Hz,Single
phase.Ambient 5°C to 50°C, RH upto 90%.
|
| |
|
| V-02435 |
SWITCHING UNIT
Specifically designed to operate Air conditioner up to 2 Ton/Heat convector upto 4.4. KVA load or 110 tube lights. Input 200-240 VAC, 50 Hz, single phase.Ambient 5°C to 50°C, RH upto 90%. |
| |
|
| V-02436 |
HEAT
CONVECTOR
Specifically designed for Tissue Culture Rooms,
Hardening Rooms or any other related work.
Specificaions: In built auto thermal cut
off device, Biotech grade 2/2.4 KW heater, variable
speed selector switch, selective combustive material
chosen for minimum utilisation for atmospheric oxygen,
Input 200-240 VAC, 50 Hz, single phase, Ambient
5°C to 50°C, RH upto 90%. |
| |
|
| V-023043 |
FLUORESCENT
TUBE LIGHT (PHILIPS/OSRAM MAKE) 40/58W
Standard designs provided. |
| |
|
| V-023044 |
PHOTOSYNTHETICALLY
ACTIVE RADIATION LIGHT (PAR)
According to DIN & IEC standard (Spectrum 380 nm
- 780 nm) |
| |
|
| V-023045 |
BALLAST
SOLID STATE FOR SIMULATED LIGHT
Electronic simulator to operate fluorescent tube
40/58 watt.
Specificaions: Natural simulated light spectrum,
flicker free radiations, low voltage start, plus
0.8 power factor, resistant to stroboscopic effect,
no RF leakage, Operating range 100 V - 300 v minimum
power consuption. Light inensity 6 Klux at 20 cm
and performance certified by Directorate Ministry
of Information Technology, Govt. of India, vide
certificate no. ERTL(N)90(A)-2KICO685. |
| |
|
| V-023046 |
PHOTOSIMULATOR
FOR PAR
(PHOTOSYNTHETICALLY ACTIVE RADIATION)LIGHT
Electronic simulator to operate PAR Light 36 watt
having wave length 380 nm - 780nm
Specificaions: Natural simulated light spectrum,
flicker free radiations, low voltage start, plus
0.8 power factor, resistant to stroboscopic effect,
no RF leakage, Operating range 100 V - 300 v minimum
heat losses, minimum power consuption. Light intensity6
Klux at 15 cm distance and 8 Klux at source ERTL
tested and approved. |
| |
|
| V-02437 |
DIGITAL
LUX METER
A hand held digital light meter with integral sensor
indicating light intensities in lux.
Specificaions: The sensor, conisting of selenium
photovoltiac cells is connected to he meter by a
1 meter coiled lead.
• 3 switch selectable ranges : • 0.1999
lux (resolution 1 lux) • 1999-19999 lux (resolution
10 lux) • 19999-50,000 lux (resolution 100
lux) • Accuracy typically ± 10% of reading
-2counts • 31/2 digit, • 13mm high Liquid
Crystal Display • Requires 9V PP3 battery for
operation. |
| |
|
| V-02438 |
DIGITAL
LUX METER
A hand held digital light meter for indicating light
intensities in lux.
Specificaions: The sensor connects to the
base of the meter via 5 pin DIN connector and a
1 meter coiled lead.
• 3 switch selectable ranges : • 0.2000
lux (resolution 1 lux) • 2000-20.000 lux (resolution
10 lux) • 20,000-100,000 lux (resolution 100
lux) • Accuracy typically ± 9% •
Display hold • 3½ digit 13mm high Liquid
Crystal Display. |
|
|
| |
|
|
| |
| V-0230 |
TISSUE
CULTURE CASTOR RACK
Used for Tissue culture, Hardening & related
work. Provides natural simulated light.
Specifications: Height 5' 8",
Width 4' 2", Lenght 18", Shelves
5, lighting facility in 4 shelves. Shelf
to shelf distance 16". Shelf 50"
x 18", 3mm thick glass / Hylem Citylam
sheet in each shelf. Four tube lights 40
Wattflourescent cription filled and 4 x
25 Watt incandescent lamps with individual
on/off switch in each shelf. Light intensity
3 Klux 5cm above the shelf surface 10 klux
at the source. Sixteen Solid State Ballats
(Code V-023045), Electronic ballasts are
specially tested and approved by ERTL for
use upto 300 V. Frame mild seel 2.5 x 2.5
cm C.R.C. sq. pipe with anti corossive,
humidity resistant Powder Coating, Caster
-4., Trolly can be connected directly to
Photoperiodic timer output, (Code V-02413
or V-02415).
Input : 200-240V A.C, 50 Hz, Single
Phase, Ambient 5 Degree C to 50 degree C,RH
upto 95. |
|
 |
|
|
| |
| V-0231 |
TISSUE
CULTURE CASTOR RACK
With PAR (Photosynthetically Active Radiation)
light used for Tissue culture, Hardening
and related work for higher carbon fixation
and night break technique by providing natural
spectrum of light intensity having wave
length 380 nm-780 nm.
Specifications: Height 5' 8",
Width 4' 2", Lenght 18", Shelves
5, lighting facility in 4 shelves. Shelf
to shelf distance 16". Shelf 50"
x 18", 3 thick glass / Hylem Citylam
sheet in each shelf. 4 x 36 Watt PAR (Photosynthetically
active radiation) lamps in one shelf with
individual on/off switch. Four tube lights
40 Wattflourescent cription filled and 4
x 25 Watt incandescent lamps with individual
on/off switch in each shelf. Light intensity
3 Klux 5cm above the shelf surface 10 klux
at the source. Sixteen Solid State Photonimulaor
(Code V-023046), frame mild steel 2.5 x
2.5 cm C.R.C. sq. pipe with anti corossive,
humidity resistant Powder Coated, Caster
-4., Trolly can be connected directly to
Photoperiodic timer output, (Code V-02413
or V-02415).
Input : 200-240 V,AC,50 Hz,Single
phase, Ambient 5 oC to 50 oC,Rh upto 95% |
| |
|
| V-0232 |
TISSUE
CULTURE CASTOR RACK (SS)
Basically Code V-0230 with stainless steel
structure. |
| |
|
| V-0233 |
TISSUE
CULTURE CASTOR RACK (SS) PLATINUM
Basically Code V-0230 with stainless Steel
Structure with Photosimulator electronic
ballast.
|
|
 |
|
|
| |
|
|
| |
|
|
|
|
|
| |
© 2004 Vista Biocell Pvt. Ltd. All right reserved. |
 |
|
|